Views
3 years ago

ECOTECH Spirant BAM spec sheet

  • Text
  • Spirant
  • Particulate
  • Filter
  • Ecotech
  • Ambient
  • Hourly
  • Span
  • Heater
  • Aurora
  • Spec
ECOTECH Spirant BAM spec sheet

SPECIFICATIONS Accuracy:

SPECIFICATIONS Accuracy: Measurement resolution: Display Resolution: Detection limit: Range: Optional ranges: Measurement cycle time: Flow rate: Filter tape: Span check: Beta source: Beta detector type: Operating temperature: Ambient temperature: Ambient humidity: Sample humidity control: Power supply: Power consumption: Dimensions: Weight: Exceeds US EPA Class III PM 2.5 FEM standards for additive and multiplicative bias 0.1 μg / m 3 1 μg / m 3 (2σ) 1 hr: < 4.8 µg / m 3 (3.6 μg / m 3 typical) (2σ) 24 hr: < 1.0 µg /m 3 1 mg (1000 μg) default setting. Settable from 0.1 mg to 10 mg Available on request 1 hour 16.7 litres/minute adjustable 0 - 20 LPM range actual or standardised flow Continuous glass fiber filter tape Automatic 0.800 mg (typical) span foil, verified hourly 14 C (carbon - 14), 60 µCi ± 15 µCi (< 2.22 x 10 6 Beq), half-life 5730 years Photomultiplier tube with organic plastic scintillator 0 to + 50 °C - 40 to + 55 °C (BX - 596 AT sensor) - 30 to + 50 °C (BX - 592) Extended range of sensors available 0 - 90 % RH, noncondensing Active Smart Heater module, 10 - 99 % RH setpoint 100 - 230 VAC, 50 / 60 Hz. Factory configured 110 V: 262 W max with Medo pump and inlet heater running (642 W with Gast pump) 230 V: 312 W max with Medo pump and inlet heater running (717 W with Gast pump) 310 x 430 x 400 mm 24.5 kg without external accessories COMMUNICATION User interface: • Menu-driven interface, 8 line 40 character LCD display & keypad Analog output: • Isolated 0 - 1 VDC output standard • 0 - 10 V, 4 - 20 mA, 0 - 16 mA switch selectable Serial interface: • RS232 two-way serial port for PC or modem communications Printer output: • Output only serial port for data or diagnostic output to a PC or serial printer Telemetry inputs: • Clock reset (voltage or contact closure), telemeter fault (contact closure) Alarm contact closures: • Data error, tape fault, flow error, power failure, maintenance Error reporting: • User-configurable available through serial port, display, and relay outputs Memory: • 4369 records (182 days at 1 record/hr) OPTIONS RTPM: • Real-time particulate monitor provides one minute measurements Aurora Interface: • Enables interfacing of Spirant with Aurora 2000 Nephelometer for one minute measurements (requires Aurora 2000 Integrating Nephelometer) Sample inlets: • PM 10 , PM 2.5 & TSP available FS 603790 OHS 603791 Ecotech Pty Ltd 1492 Ferntree Gully Road Knoxfield VIC 3180 Melbourne Australia +61 3 9730 7800 email@ecotech.com ecotech.com Specifications subject to change without notice. Spirant, Airodis, Aurora are trademarks or registered trademarks of Ecotech Pty Ltd in the United States and/or other countries. © 2020 Ecotech Pty Ltd. All rights reserved. 20201027

Brochures

Spec Sheets

TOGETHER

01dB

Brochures

Spec Sheets

"Very efficient. Competitive pricing. The reminders, I’m so busy in my job that it’s so great to have a reminder to do something. It really helps me.
I’m very happy".

- Tim Cannon – Research and Development Manager; Pecan Engineering Pty Ltd