Views
1 year ago

ECOTECH Serinus 40T Trace Oxides of Nitrogen Analyser

  • Text
  • Serinus
  • Ecotech
  • Analyser
  • Analog
  • Digital
  • Rack
  • Oxides
  • Nitrogen
  • Viewing
  • Parameters
  • Www.ecotech.com
ECOTECH Serinus 40T Trace Oxides of Nitrogen Analyser

SPECIFICATIONS Range:

SPECIFICATIONS Range: Concentration units: Noise: Lower detectable limit: Linearity: Precision: Zero drift: Span drift: Response time: STP reference: Sample flow rate: Temperature range: Power: Power consumption: Dimensions: Rack Spacing: Weight: COMMUNICATION 0 - 2000 ppb (autoranging) mg/m 3 , μg/m 3 , ng/m 3 , ppm, ppb or ppt < 25 ppt < 50 ppt (with Kalman filter enabled) ± 1 % of full scale 100 ppt or 0.5 % of reading whichever is greater 24 hours: < 100 ppt 24 hours: < 1 % of reading or 2 ppb whichever is greater 15 seconds to 95 % 0 °C, 20 °C, 25 °C at 101.3 kPa 820 cc/min (total for 2 channels) 0 - 40 °C 100 - 240 VAC, 50 - 60 Hz (autoranging) 265 VA (max at start-up) 190 VA (nominal) 429 x 175 x 638 mm 3.5 RU 21.9 kg DATA LOGGING 8 GB removable USB flash memory drive that stores the following: • Internal data logger (can log up to 12 of 200+ parameters) • Event log • Automatic/Manual configuration backup • Automatic/Manual parameter list save • Logger interval (1 second to 24 hours) • Storage capacity ~ 10 years (set to 1 minute intervals). OPTIONS & ACCESSORIES • TCP/IP Network Port • Dual Sample (particulate) Filter • High Pressure Span (for direct cylinder calibration) • High Pressure Zero (for direct cylinder calibration) • Test Lamp (for PMT diagnostics) • Metric Fitting Kit (to connect 6 mm tube to rear ports) • 19” Rack Mount Kit • High Vacuum External Pump (240 or 110 VAC) • External Charcoal Scrubber • Annual Maintenance Kit • Printed User Manual (a soft copy of the user manual is supplied on the ECOTECH resources USB stick with each analyser). • #1 RS232 port (supports all protocols*) • #2 RS232 port (supports all protocols* and multidrop) • USB port (Advanced protocol only) • Bluetooth (Advanced protocol only) • TCP/IP network port (optional, supports all protocols*). *Avaliable protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800 or Advanced COMMUNICATION ANALOG & DIGITAL I/O PORT: • 3 x analog outputs (current or voltage), 12 bit resolution user definable range (between two user specified points) Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mA Voltage range: 0 - 5 V, 0 - 10 V (voltage offset of 0 V, 0.25 V or 0.5 V) • 3 x analog inputs (scalable), 0 - 5 V, 16 bit resolution • 8 x logic level digital control inputs • 8 x open collector digital status outputs. FS 603790 OHS 603791 ECOTECH Pty Ltd (Global Head Office) 1492 Ferntree Gully Road Knoxfield VIC 3180 Melbourne Australia +61 3 9730 7800 email@ecotech.com ecotech.com Specifications subject to change without notice. Images used are for illustrative purposes only. Ecotech & Serinus are trademarks or registered trademarks of ECOTECH Pty Ltd in the United States and/or other countries. © 2019 ECOTECH Pty Ltd. All Rights Reserved. 20191031

Brochures

Spec Sheets

TOGETHER

01dB

Brochures

Spec Sheets

"Very efficient. Competitive pricing. The reminders, I’m so busy in my job that it’s so great to have a reminder to do something. It really helps me.
I’m very happy".

- Tim Cannon – Research and Development Manager; Pecan Engineering Pty Ltd