Features • Performs

Features • Performs single & multi-point calibrations using the Serinus Calibrator’s precision mass flow controllers, for utmost confidence in the results • Designed & developed with wide-ranging customer input for easy, intuitive, accurate use. • Performs calibration manually through user interface or remotely via RS232, USB networks or digital inputs Dilution & span flows Dilution gas inputs: Source gas inputs: Dilution mass flow controller: Source mass flow controller: Flow accuracy (constant temp): Flow repeatability: Linearity: Operating gas pressure: Zero drift: Response time: Output manifold: Dilution ratio: Case dimensions rack length: Total length (with latch release): Chassis width: Front panel width: Chassis height: Front panel height: Weight: 1 standard 100 - 200 kPa (g) (2 optional) 4 standard 100 - 200 kPa (g) (8 optional) 10 SLPM, 0 Deg, 1 ATM (std), 1 SLPM, 2 SLPM, 5 SLPM or 20 SLPM (optional), 2nd MFC (optional) 50 SCCM, 0 Deg, 1 ATM (std), 10 SCCM, 20 SCCM, 100 SCCM, 500 SCCM or 1 SLPM, 2 SLPM (optional), 2nd MFC (optional) Within 1 % of full scale Within 0.15 % of full scale Within 0.15 % of full scale 100 - 200 kPa < 0.6 % per year < 5 seconds 4 output ports standard Variable 10:1 to 2000:1 (std configuration) 597 mm (23.5”) (front to rear) 638 mm (25.1”) 418 mm (16.5”) 429 mm (16.9”) 163 mm / uses 4RU (6.4”) 175 mm (6.9”) 18.2 kg acoem.com | 2

Communication User interface: Programmable calibrations: Analog input: Digital output: Via front panel keypad or computer 16 separate programmable sequences 32 separate programmable points Three analog voltage inputs (0 - 5 VDC) CAT I rated RS232 port #1: Normal digital communication RS232 port #2: Multidrop port used for multiple analyser connections on a single RS232 USB port connection on rear panel 25 pin connector with discrete status & user control USB stick memory (front panel) for data logging, event logging & parameter storage 8 Digital Outputs, open collector max 400 mA each at 12 VDC (max total output 2A) 8 Digital Inputs, 0 - 5 VDC CAT I rated 1 Diluent Control, + 12 V output. Power Operating voltage: Power consumption: Operating conditions ambient temperature range: Pressure: 100 - 240 V VAC 50 / 60 Hz (autoranging) 165 VA maximum (typical at start-up) 95 VA after warm-up 0 - 45 °C (32 - 104 °F), 20 - 35 °C for optimum performance Maximum altitude: 3000 m above sea level. acoem.com | 3

Brochures

Spec Sheets

TOGETHER

01dB

Brochures

Specsheets

"Very efficient. Competitive pricing. The reminders, I’m so busy in my job that it’s so great to have a reminder to do something. It really helps me.
I’m very happy".

- Tim Cannon – Research and Development Manager; Pecan Engineering Pty Ltd