Acoem.Ecotech
Views
3 years ago

ACOEM HS-AC334-Diagram

HS-AC334-Diagram

ACOEM

Connection Details of Cable Assembly .-----------------------Black core .---------------------- Screen/Drain Wire .-------------------White core Inside View of Cable Outside View of Connector 2 Pin MS Overmoulded Straight Socket Connector with 316 Stainless Steel Locking Ring Connector sealed to IP68 only when connected to the accelerometer. Free end Pos 1. 2. 3. 4. Environment Specification of Cable Assembly Maximum operating temperature of 150 ° C with high levels of resistance to chemical attack. Description Tin plated copper conductor insulation of FEP Tin plated copper drain wire Braided screen of tin plated copper wire Jacket of FEP, blue Materials of Cable: High Temperature FEP Cable Dimension 20AWG 20AWG 16x 6x 0.127 Thickness 0.35mm Overall Diameter Copper 0.96 Insulation 1.47 0.96 3.3.8 4.5 Remarks 19 X 0.2 19 X 0.2 Optimised: 85% min Tube-Extruded Technical Data of Cable Technical Data Values at 20 ° C Unit Conductor Resistance 34 0/ km Insulation Resistance >5000 MOx km Test Voltage 3 KVDC Voltage Rating 600/1000 VAC Capacitance Core-core: 85 pF / m Inductance 0.54 1kHz µH/m L/R Ratio 7.94 µH/0 Weight 40 g Im Temperature Rating -80 / +200 oc ACOEM Australia 8/69 Sir Donald Bradman Drive Hilton SA 5033 Adelaide Australia +61 (0)8 8355 8000 [email protected] HS-AC334 Issue C

Copied successfully!

Brochures

Spec Sheets

TOGETHER

01dB

Brochures

Specsheets

"Very efficient. Competitive pricing. The reminders, I’m so busy in my job that it’s so great to have a reminder to do something. It really helps me.
I’m very happy".

- Tim Cannon – Research and Development Manager; Pecan Engineering Pty Ltd