SPECIFICATIONS Range:

SPECIFICATIONS Range: Concentration units: Noise: Lower detectable limit: Linearity: Precision: Zero drift: Span drift: Response time: STP reference: Sample flow rate: Temperature range: Power: Power consumption: Dimensions: Rack Spacing: Weight: 0 to 200 ppm (autoranging) mg/m 3 , μg/m 3 , ng/m 3 , ppm, ppb or ppt < 0.02 ppm or 0.2 % of concentration reading whichever is greater < 0.04 ppm < 1 % of full scale (0 - 50 ppm) 0.1 ppm or 0.1 % of reading whichever is greater 24 hours: < 0.1 ppm 7 days: < 0.1 ppm 7 days: < 0.5 % of reading or 0.1 ppm whichever is greater 60 seconds to 95 % 0 °C, 20 °C, 25 °C at 101.3 kPa 1000 cc/min 0 to 40 °C 100 - 240 VAC, 50 - 60 Hz (autoranging) 260 VA (max at start-up) 150 VA (nominal) 429 x 175 x 638 mm 3.5 RU 17.8 kg DATA LOGGING • 8 GB removable USB flash memory drive that stores the internal data logger, event log, automatic/manual configuration backup and automatic/manual parameter list save • Internal data logger (can log up to 12 of 200+ parameters) • Logger interval (1 second to 24 hours) • Storage capacity ~ 10 years (set to 1 minute interval). OPTIONS & ACCESSORIES • TCP/IP Network Port • Dual Sample (particulate) Filter • High Pressure Span (for direct cylinder calibration) • High Pressure Zero (for direct cylinder calibration) • Internal DC Pump (long life, low power, minimal maintenance) • Integrated CO 2 Sensor (range: 0 - 2000 ppm, accuracy: ± 2 %) • Metric Fitting Kit (to connect 6 mm tube to rear ports) • 19” Rack Mount Kit • External Pump (240 or 110 VAC) • Annual Maintenance Kit • Printed User Manual (a soft copy of the user manual is supplied on the ACOEM Ecotech resources USB stick with each analyser). COMMUNICATION • #1 RS232 port (supports all protocols*) • #2 RS232 port (supports all protocols* and multidrop) • USB port (Advanced protocol only) • Bluetooth (Advanced protocol only) • TCP/IP network port (optional, supports all protocols*). *Available protocols: Modbus (RTU/TCP), Bayern Hessen, EC9800 or Advanced COMMUNICATION ANALOG & DIGITAL I/O PORT: • 3 x analog outputs (current or voltage), 12 bit resolution user definable range (between two user specified points) Current range: 0 - 20 mA, 2 - 20 mA or 4 - 20 mA Voltage range: 0 - 5 V, 0 - 10 V (voltage offset of 0 V, 0.25 V or 0.5 V) • 3 x analog inputs (scalable), 0 - 5 V, 16 bit resolution • 8 x logic level digital control inputs • 8 x open collector digital status outputs. FS 603790 OHS 603791 ACOEM Ecotech 1492 Ferntree Gully Road Knoxfield VIC 3180 Melbourne Australia +61 3 9730 7800 [email protected] ecotech.com Specifications subject to change without notice. Images used are for illustrative purposes only. Ecotech & Serinus are trademarks or registered trademarks of Ecotech Pty Ltd in the United States and/or other countries. © 2020 Ecotech Pty Ltd. All Rights Reserved. 20201014

Brochures

Spec Sheets

TOGETHER

01dB

Brochures

Specsheets

"Very efficient. Competitive pricing. The reminders, I’m so busy in my job that it’s so great to have a reminder to do something. It really helps me.
I’m very happy".

- Tim Cannon – Research and Development Manager; Pecan Engineering Pty Ltd