Views
1 year ago

ECOTECH Aurora 1000 spec sheet

ECOTECH Aurora 1000 spec sheet

ECOTECH Aurora 1000 spec

Aurora 1000 INTEGRATING NEPHELOMETER Easy to use and maintain, the Aurora 1000 lowers the cost of ownership for aerosol light scattering, visibility and particulate monitoring instrumentation. The Aurora 1000 Integrating Nephelometer uses a single wavelength for scattering coefficient visibility measurements at one of three user specified wavelengths. ECOTECH, through collaboration with globally renowned atmospheric research institutes, now provides the scientific community with the most advanced commercially available nephelometers. Using a single wavelength LED light source, the Aurora 1000 can be equipped with any of the following light sources: • 450 nm (blue) for fine and ultra fine particulates (wood fires, automobiles) • 525 nm (green) for visibility • 635 nm (red) for large particulates (e.g. pollen, sea salt). BENEFITS • Simplified automatic calibration using internal valves, ideal for remote locations. Fully automatic zero check or adjust, automatic span check or automatic zero and span check available in intervals of 1, 3, 6, 12, 24 hrs or weekly • Fully integrated package including: internal sample pump, sample heater, internal calibration valves, zero air pump and data logger • Internal sample heater with temperature or RH control, which can be enabled by the user to eliminate the effects of humidity (RH: < 30 to < 90 % ) • 12 VDC operation (60 watts max, 13 watts nominal) • Holds up to 61 days of 5 minute data averages or 2 days of 1 min data • Data downloading and firmware upgrading software supplied on USB or internet. Increased accuracy • Automatic calibration • Easy maintenance/cleaning of the measurement cell • Long lasting LED light source • Intuitive software and maintenance • Automatic optical reference calibration • Facilitates a wide measurement range (0 to 20,000 Mm -1 ). LED vs flash lamp • Our LED light source is guaranteed not to fail and often exceeds 5 years, compared to a flash lamp that is recommended to be changed every 4 - 6 months • Heat generated by the LED light source is a fraction of that generated by a flash lamp, minimising changes in sample RH • LEDs emit light at a specific wavelength eliminating the need for band pass filters. Lower cost of ownership • Fully automatic zero and span calibrations • Low power internal 12 V heater eliminates the need for external inlet heater • Long lasting low power LED light source • No bandpass filters to be replaced • Unique in its simplicity and practicality.

Brochures

Spec Sheets

TOGETHER

01dB

Brochures

ACOEM Environment Nordic Environmental Monitoring brochure
ACOEM Environment Smart Cities Environmental Monitoring, 01dB & ECOTECH brochure
ECOTECH AQMesh brochure and spec sheet
ECOTECH Ambient Air Brochure
ECOTECH Asset Management System - AMS - brochure
ECOTECH Aurora Integrating Nephelometers
ECOTECH Blast Monitoring brochure
ECOTECH Calibration Services brochure
ECOTECH Company Profile
ECOTECH Congrego Data Logger brochure
ECOTECH Continuous Emissions Monitoring Systems (CEMS) Brochure
ECOTECH Europe Solution Snapshot brochure
ECOTECH India Solution Snapshot brochure
ECOTECH Integrated Noise Monitoring Systems brochure
ECOTECH Integro LIDAR Network brochure
ECOTECH NATA Accreditation brochure
ECOTECH Operations and Maintenance brochure
ECOTECH Palas Fidas 200 Brochure
ECOTECH Serinus 60 NO2 Gas Analyser
ECOTECH Serinus Gas Calibrators
ECOTECH Solution Snapshot brochure
ECOTECH Spectronus FTIR brochure
ECOTECH Water Product Portfolio Brochure
ECOTECH Water Services brochure
ECOTECH MAXX Portable &amp; Fixed Site Samplers brochure
ECOTECH Sintrol Dumo brochure
ACOEM Smart Industry Reliability Services Solution Snapshot brochure
ACOEM FIXTURLASER LASER Geometry Measurements brochure
ACOEM FIXTURLASER LASER KIT brochure
ACOEM FIXTURLASER LASER SMC brochure
ACOEM FIXTURLASER LASER OL2R brochure
ACOEM FIXTURLASER NXA brochure
ACOEM FIXTURLASER NXA Pro brochure
ACOEM CTC Vibration Analysis Hardware for the Paper Industry brochure
ACOEM CTC PRO (Protection Reliability Optimization) Vibration Switch Kits brochure
ACOEM CTC PPS Connector Series brochure

Spec Sheets

ECOTECH Serinus 10 O3 Gas Analyser spec sheet
ECOTECH Serinus 30 CO Gas Analyser spec sheet
ECOTECH Serinus 40 NOx Gas Analyser spec sheet
ECOTECH Serinus 50 SO2 Gas Analyser spec sheet
ECOTECH Serinus 44 NOx Gas Analyser spec sheet
ECOTECH Serinus 60 spec sheet
ECOTECH Serinus 51 SO2-H2S Analyser spec sheet
ECOTECH Serinus 57 Total Reduced Sulfur (TRS) Analyser
ECOTECH Serinus Cal 1000 spec sheet
ECOTECH Serinus Cal 2000 spec sheet
ECOTECH Serinus Cal 3000 spec sheet
ECOTECH Serinus 31 CO2 Carbon Dioxide Analyser spec sheet
ECOTECH Aurora 1000 spec sheet
ECOTECH Aurora 2000 spec sheet
ECOTECH Aurora 3000 spec sheet
ECOTECH Aurora 4000 spec sheet
ACOEM Environment AETHLABS microAeth AE51
ACOEM Environment AETHLABS microAeth MA200 Black Carbon Monitor
ACOEM Environment AETHLABS microAeth MA300 Black Carbon Monitor
ACOEM Environment AETHLABS microAeth MA350 Black Carbon Monitor
ECOTECH Air 1000 spec sheet
ECOTECH Calibration Services brochure
ECOTECH Certa 1000 spec sheet
ECOTECH HiVol 3000 spec sheet
ECOTECH Met One Instruments E-FRM Particulate Sampler
ECOTECH MicroVol 1100 spec sheet
ECOTECH Model 8301 Series Zero Air Generators spec sheet
ECOTECH Model 8302 Dilution Probe Controller
ECOTECH NATA Accreditation brochure
ECOTECH Protinus 1000 spec sheet
ECOTECH BAM 1022 spec sheet
ECOTECH Exactus BAM spec sheet
ECOTECH Spirant BAM spec sheet

TOGETHER Magazine

TOGETHER - Future Forward Stories Past
ECOTECH TOGETHER magazine Issue 1
ECOTECH TOGETHER magazine Issue 2
ECOTECH TOGETHER magazine Issue 3
ECOTECH TOGETHER Magazine Issue 4
ECOTECH TOGETHER Magazine Issue 5
ECOTECH TOGETHER Magazine Issue 6

© 2018 Ecotech