Views
5 months ago

ACOEM FIXTURLASER NXA Pro brochure

ACOEM FIXTURLASER NXA Pro brochure

Features Fixturlaser

Features Fixturlaser NXA Pro OmniView The OmniView function shows the machine from the same side as the user is positioned. Thanks to the built-in gyroscope the Fixturlaser NXA Pro is capable of keeping track of both you and the machine! VertiZontal Moves If the machine is misaligned, you will be recommended to go to a shims result view. The Fixturlaser NXA Pro calculates how much you need to remove or add shims in order to correct the machine vertically. When moving on to horizontal correction, the system goes live and will deliver real time values during the adjustment phase. No remeasurements in between adjustments are necessary, as you are never in doubt of the machine’s true position. Sensor technology We have chosen to use CCD technology in our sensors, a digital technology commonly used in all digital cameras. The benefit over the older analog PSD technology is unmatched with regards to the capability of filtering and refining the measurement data. With this second generation scientific grade CCD sensor, we can now obtain an unparalleled repeatability together with outstanding results regardless of ambient light and measurement environment. With dual high performance inclinometers in each head, and the improved algorithms, we provide precision alignment at a completely new level.

Fixturlaser NXA Pro System Weight including all standard parts: Dimension: Display Unit Weight: Dimensions: Environmental protection: Display size: Gyroscope: Operating time Battery charging time (system off, room temperature): TD Units Weight: Dimensions: Environmental protection: Measurement distance: Detector: Detector length: 7,7 kg (17 lbs) 415 mm x 325 mm x 180 mm (16 in x 13 in x 7 in) 1,2 kg (2,6 lbs) with battery 124 mm x 158 mm x 49 mm (4,9 in x 6,2 in x 1,9 in) IP 65 (Dust tight and protected against water jets) 6,5” (165 mm) diagonal (133 x 100 mm) 6-Axis MEMS Inertial Motion Sensor with drift compen sation and automatic field calibration. 10 hours continuous use (with 50% LCD backlight) 1 hour charge – 6 hours operating time M3 212 g (7,5 oz) S3 188 g (6,6 oz) 92 mm x 77 mm x 33 mm (3,6 in x 3,0 in x 1,3 in) IP 65 (Dust tight and protected against water jets) Up to 10 m 2nd generation Ultra HD CCD 30 mm (1,2 in) Detector resolution: 1 µm Measurement accuracy: 0,3% ± 7 µm Gyroscope: Operating time: 6-Axis MEMS Inertial Motion Sensor with drift compens tion and automatic field calibration 17 hours continuous use (measuring) Shaft Brackets Shaft diameter: Rods: Ø 25 – 175 mm (1in – 6.9in) With extension chain Ø 25 – 450 mm (1in – 18in) 4 pcs 85 mm and 4 pcs 160 mm (extendable to 245 mm) Fixturlaser NXA Pro Application Horizontal Shaft Alignment Determine and correct the relative position of two horizontally mounted machines that are connected, such as a motor and a pump, so that the rotational centers of the shafts are collinear. Vertical Shaft Alignment Determine and correct the relative position of two vertically/flange mounted machines that are connected, such as a motor and a pump, so that the rotational centers of the shafts are collinear. Machine Train Alignment Align a set-up of more than two rotating machines that are connected to each other. Machine Defined Data Information such as entered distances, measurement method, target values and tolerances are saved in a template. Feetlock Solution to solve base-bound and/or bolt-bound machines. Memory Manager Measurements can be organized in folders and subfolders. Single measurements and/or complete data structures can be copied to USB stick. Softcheck Softcheck checks if there is a soft foot condition, i.e. when the motor is not resting firmly on all its feet. Target Values Pre-set target values before starting your alignment work when you have determined the machines thermal expansion. Hot Check Performing a measurement just after the machine has been shut off, and another measurement when the machine is cold. The Hot Check application is then used to compare these two measurements. The difference between the two measurements can be used as target values when shaft alignment is performed.

Brochures

Spec Sheets

TOGETHER

01dB

Brochures

ACOEM Environment Nordic Environmental Monitoring brochure
ACOEM Environment Smart Cities Environmental Monitoring, 01dB & ECOTECH brochure
ECOTECH AQMesh brochure and spec sheet
ECOTECH Ambient Air Brochure
ECOTECH Asset Management System - AMS - brochure
ECOTECH Aurora Integrating Nephelometers
ECOTECH Blast Monitoring brochure
ECOTECH Calibration Services brochure
ECOTECH Company Profile
ECOTECH Congrego Data Logger brochure
ECOTECH Continuous Emissions Monitoring Systems (CEMS) Brochure
ECOTECH Europe Solution Snapshot brochure
ECOTECH India Solution Snapshot brochure
ECOTECH Integrated Noise Monitoring Systems brochure
ECOTECH Integro LIDAR Network brochure
ECOTECH NATA Accreditation brochure
ECOTECH Operations and Maintenance brochure
ECOTECH Palas Fidas 200 brochure
ECOTECH Serinus 60 NO2 Gas Analyser
ECOTECH Serinus Gas Calibrators
ECOTECH Solution Snapshot brochure
ECOTECH Spectronus FTIR brochure
ECOTECH Water Product Portfolio Brochure
ECOTECH Water Services brochure
ECOTECH MAXX Portable & Fixed Site Samplers brochure
ECOTECH Sintrol Dumo brochure
ACOEM Smart Industry Reliability Services Solution Snapshot brochure
ACOEM FIXTURLASER LASER Geometry Measurements brochure
ACOEM FIXTURLASER LASER KIT brochure
ACOEM FIXTURLASER LASER SMC brochure
ACOEM FIXTURLASER LASER OL2R brochure
ACOEM FIXTURLASER NXA brochure
ACOEM FIXTURLASER NXA Pro brochure
ACOEM CTC Vibration Monitoring & Machinery Protection Product Overview brochure
ACOEM CTC Vibration Analysis Hardware for the Paper Industry brochure
ACOEM CTC PRO Protection & Reliability Optimisation Instruments brochure
ACOEM CTC PRO Headquarters brochure
ACOEM CTC PRO (Protection & Reliability Optimisation) Vibration Switch Kits brochure
ACOEM CTC KT-DA1001 Series Proximity Probe Kit brochure
ACOEM CTC PPS Connector Series brochure
ACOEM Healthy Schools Index (HSI) brochure

Spec Sheets

ECOTECH Serinus 10 O3 Gas Analyser spec sheet
ECOTECH Serinus 30 CO Gas Analyser spec sheet
ECOTECH Serinus 40 NOx Gas Analyser spec sheet
ECOTECH Serinus 50 SO2 Gas Analyser spec sheet
ECOTECH Serinus 44 NOx Gas Analyser spec sheet
ECOTECH Serinus 60 spec sheet
ECOTECH Serinus 51 SO2-H2S Analyser spec sheet
ECOTECH Serinus 57 Total Reduced Sulfur (TRS) Analyser
ECOTECH Serinus Cal 1000 spec sheet
ECOTECH Serinus Cal 2000 spec sheet
ECOTECH Serinus Cal 3000 spec sheet
ECOTECH Serinus 31 CO2 Carbon Dioxide Analyser spec sheet
ECOTECH Serinus 40T Trace Oxides of Nitrogen Analyser
ECOTECH Serinus 50T Trace Sulfur Dioxide Analyser
ECOTECH Aurora 1000 spec sheet
ECOTECH Aurora 2000 spec sheet
ECOTECH Aurora 3000 spec sheet
ECOTECH Aurora 4000 spec sheet
ACOEM Environment AETHLABS microAeth AE51
ACOEM Environment AETHLABS microAeth MA200 Black Carbon Monitor
ACOEM Environment AETHLABS microAeth MA300 Black Carbon Monitor
ACOEM Environment AETHLABS microAeth MA350 Black Carbon Monitor
ECOTECH ACS 1000 spec sheet
ECOTECH Air 1000 spec sheet
ECOTECH Calibration Services brochure
ECOTECH Certa 1000 spec sheet
ECOTECH HiVol 3000 spec sheet
ECOTECH Met One Instruments E-FRM Particulate Sampler
ECOTECH MicroVol 1100 spec sheet
ECOTECH Model 8301 Series Zero Air Generators spec sheet
ECOTECH Model 8302 Dilution Probe Controller
ECOTECH NATA Accreditation brochure
ECOTECH Protinus 1000 spec sheet
ECOTECH VOC 1000 Methane Analyser spec sheet
ECOTECH BAM 1022 spec sheet
ECOTECH Exactus BAM spec sheet
ECOTECH Spirant BAM spec sheet

TOGETHER Magazine

TOGETHER - Future Forward Stories Past
ECOTECH TOGETHER magazine Issue 1
ECOTECH TOGETHER magazine Issue 2
ECOTECH TOGETHER magazine Issue 3
ECOTECH TOGETHER Magazine Issue 4
ECOTECH TOGETHER Magazine Issue 5
ECOTECH TOGETHER Magazine Issue 6
ECOTECH Together Magazine Issue 7

© 2018 Ecotech